MACX MCR-VDC

MACX MCR-VDC

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    PHOENIX CONTACT - MACX MCR-VDC - Voltage Transducer, MACX Series, -660 to 660 Vdc, 24 Vdc, 1 %, -10 ...

  • 数据手册
  • 价格&库存
MACX MCR-VDC 数据手册
https://www.phoenixcontact.com/gb/products/2906242 Voltage measuring transducers - MACX MCR-VDC - 2906242 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) MACX MCR voltage transducers for DC voltages of 0... (+/-) 20 V DC to 0.. .(+/-) 660 V DC, output signal (+/-) 10 V/ (+/-)20 mA Why buy this product  Adjustable voltage ranges  Bidirectional output signals  3-way isolation  ZERO/SPAN adjustment ±20%  Tool-free parameterization of measured values  Teach-in configuration of the measured value range Key Commercial Data Packing unit 1 STK GTIN GTIN 4055626050928 Weight per Piece (excluding packing) 197.700 g Custom tariff number 85437090 Country of origin Germany Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 22.5 mm Height 99 mm Depth 114.5 mm Ambient conditions 12/26/2016   Page 1 / 5 https://www.phoenixcontact.com/gb/products/2906242 Voltage measuring transducers - MACX MCR-VDC - 2906242 Technical data Ambient conditions Ambient temperature (operation) -25 °C ... 60 °C Ambient temperature (storage/transport) -40 °C ... 85 °C (non-condensing) Maximum altitude ≤ 2000 m Degree of protection IP20 Input data Input voltage range -550 V DC ... 550 V DC Input resistance 5500 kΩ Input voltage range -370 V DC ... 370 V DC Input resistance 3700 kΩ Input voltage range -170 V DC ... 170 V DC Input resistance 1700 kΩ Input voltage range -120 V DC ... 120 V DC Input resistance 1200 kΩ Input voltage range -80 V DC ... 80 V DC Input resistance 800 kΩ Input voltage range -54 V DC ... 54 V DC Input resistance 540 kΩ Input voltage range -36 V DC ... 36 V DC Input resistance 360 kΩ Nom. voltage ± 660 V DC Output data Output name Voltage output Voltage output signal -10 V ... 10 V Max. output voltage ≤ 11 V Load/output load voltage output > 10 kΩ Ripple 50 mV Output name Current output Current output signal -20 mA ... 20 mA Max. output current ≤ 22 mA Load/output load current output < 500 Ω Power supply Nominal supply voltage 24 V DC (-20 % ... +25 %) Supply voltage range 19.2 V DC ... 30 V DC Max. current consumption < 60 mA Connection data Connection method Pluggable screw connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section AWG min. 24 12/26/2016   Page 2 / 5 https://www.phoenixcontact.com/gb/products/2906242 Voltage measuring transducers - MACX MCR-VDC - 2906242 Technical data Connection data Conductor cross section AWG max. 14 Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Stripping length 8 mm Screw thread M3 Connection method Screw connection General Maximum transmission error < 1 % (of measuring range end value) Maximum temperature coefficient < 0.015 %/K Alignment zero ± 20 % Alignment span ± 20 % Step response (10-90%) < 16 ms Test voltage 5.3 kV AC (50 Hz, 1 min.) Overvoltage category III Degree of pollution 2 Rated insulation voltage 300 V DC Standards/regulations IEC 61010-1 IEC 61010-2-30 Electromagnetic compatibility Conformance with EMC directive Noise emission EN 61000-6-4 Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations. Color gray Mounting position any Assembly instructions Can be aligned with spacing = 10 mm Conformance CE-compliant UL, USA/Canada UL 61010 Listed Standards and Regulations Electromagnetic compatibility Conformance with EMC directive Noise emission EN 61000-6-4 Standards/regulations IEC 61010-1 IEC 61010-2-30 Low Voltage Directive Conformance with Low Voltage Directive Conformance CE-compliant UL, USA/Canada UL 61010 Listed Environmental Product Compliance China RoHS Environmentally Friendly Use Period = 50 For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” 12/26/2016   Page 3 / 5 https://www.phoenixcontact.com/gb/products/2906242 Voltage measuring transducers - MACX MCR-VDC - 2906242 Drawings Block diagram IN OUT +550 V 4.1 +370 V 4.2 +250 V 4.3 +170 V 4.4 - 3.1 3.3 3.2 3.4 +120 V 5.1 +80 V +54 V 5.2 +36 V +24 V 5.3 5.4 N 1.3 1.4 OUT I OUT U GNDI GNDU +24 VDC GND Classifications eCl@ss eCl@ss 5.0 27210190 eCl@ss 5.1 27210190 eCl@ss 6.0 27210125 eCl@ss 7.0 27210125 eCl@ss 8.0 27210125 ETIM ETIM 4.0 EC002477 ETIM 5.0 EC002477 ETIM 6.0 EC002477 Approvals Approvals Approvals UL Listed / cUL Listed / cULus Listed Ex Approvals Approval details UL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 330267 12/26/2016   Page 4 / 5 https://www.phoenixcontact.com/gb/products/2906242 Voltage measuring transducers - MACX MCR-VDC - 2906242 Approvals cUL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 330267 cULus Listed       Phoenix Contact 2016 © - all rights reserved http://www.phoenixcontact.com 12/26/2016   Page 5 / 5
MACX MCR-VDC 价格&库存

很抱歉,暂时无法提供与“MACX MCR-VDC”相匹配的价格&库存,您可以联系我们找货

免费人工找货